Lexmark C762, C760 manual 4-70, 10 PostScript Emulation System Parameters Continued

Models: C762 C760

1 402
Download 402 pages 23.32 Kb
Page 247
Image 247
4-70

4-70 change the values of system parameters and setdevparams

PostScript

Table 4-10: PostScript Emulation System Parameters (Continued)

Key

Type

Definition

 

SystemParamsPassword

string

(Write-only) Controls the ability of setsystemparams to

 

 

change the values of system parameters and setdevparams

 

 

to change the values of device parameters.

 

 

Legal value: Any integer or string of 32 or fewer non-null

 

 

characters. An integer is converted to a string.

 

 

 

UseOldcopypage3

boolean

True indicates the copypage command is processed as

 

 

defined in PostScript Level 2 description. False indicates the

 

 

copypage command is processed as defined in PostScript 3

 

 

description.

 

 

 

 

UseOldFonts3

boolean

True redefines the following PostScript resident fonts to match

 

 

the character designs and metrics defined in PostScript Level

 

 

2. The font names in parentheses are the equivalent

 

 

PostScript 3 font names for the associated PostScript Level 2

 

 

names.

 

 

 

Antique Olive

(Antique Olive Roman)

 

 

Antique Olive Bold

 

 

 

Antique Olive Italic

 

 

 

Letter Gothic

 

 

 

Letter Gothic Bold

 

 

 

Letter Gothic Italic

(Letter Gothic Slanted)

 

 

Marigold

 

 

 

Univers Bold

 

 

 

False restores the font compatibility to PostScript 3.

 

 

 

ValidNV

boolean

(Read-only) Indicates if non-volatile memory is currently used

 

 

to store persistent parameters. If this memory is found

 

 

defective during system initialization, factory defaults are

 

 

used. If further testing reveals this memory is defective, it is

 

 

not used and ValidNV is False. Otherwise, ValidNV is True.

 

 

 

WaitTimeout

integer

The value, in seconds, to which the user parameter

 

 

WaitTimeout is initialized at the beginning of each print job.

 

 

Negative values are ignored and the previous setting is used.

 

 

A value of zero indicates an infinite timeout. If you select a

 

 

number between 1 and 14, 15 is set.

 

 

Legal values: x = 0, 15 <= x <= 65355

 

 

 

 

1 These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 2016. 2 These parameters are available with the Adobe PostScript Language Supplement 3010.

3 These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 3010.

Page 247