Lexmark C762 4-72, 11 PostScript Emulation Device Parameters, PCL SmartSwitch is set to On

Models: C762 C760

1 402
Download 402 pages 23.32 Kb
Page 249
Image 249
4-72

4-72 Table 4-11: PostScript Emulation Device Parameters

PostScript

Table 4-11: PostScript Emulation Device Parameters

Key

Type

Definition

 

 

 

Device Parameters for the Communication Device %Parallel%, %ParallelA%, %ParallelB%, %ParallelC%, %ParallelD% (%Parallel_NV% and %Parallel_Pending% contain the same parameters)

DelayedOutputClose

boolean

Selects how the printer manages the port at the end of each print job. Supported values are:

 

 

True

An end-of-file message is not sent until the current job and all preceding jobs

 

 

 

finish printing.

 

 

False

An end-of-file message is sent as soon as a job finishes executing in the

 

 

 

interpreter, whether or not that job has finished printing.

 

 

This value is set independently for each port.

 

 

 

 

Enabled

boolean

(Read-only)

 

 

 

Supported values are:

 

 

True

 

 

 

False

 

 

 

 

Filtering

name

Indicates if the input needs further filtering before the data can be correctly processed.

 

 

Supported values are:

 

 

InterpreterBased

 

 

None

 

 

 

 

Handshake

integer

(Read-only) Always returns a value of 2.

 

 

 

HasNames

boolean

(Read-only) Always returns False.

 

 

 

 

Interpreter

name

(Read-only)

 

 

 

Supported values are:

 

 

PostScript

 

 

AutoSelect

 

 

PCL

 

 

 

PPDS

 

 

 

 

On

boolean

Designates if the communication channel is On and able to receive and send data.

 

 

Supported values are:

 

 

True

Data is sent and processed

 

 

False

Data is lost

 

 

 

 

OutputDevice

string

(Read-only)

 

 

 

 

PCLSmartSwitch

boolean

Supported values are:

 

 

True

PCL SmartSwitch is set to On.

 

 

False

PCL SmartSwitch is set to Off.

 

 

For more information, see “Using SmartSwitch” on page 2-1.

 

 

 

PortLocation

string

(Read-only) Designates the physical location of the port related to the parameter set.

 

 

Supported values are:

 

 

Standard Port

 

 

Option Slot 1

 

 

Option Slot 2

 

 

Option Slot 3

 

 

Option Slot 4

 

 

 

 

Page 249