2-54

PCL

 

 

 

 

 

 

Table 2-24: Status Readback

Command / Parameters

Function / Result

ESC*s#T

 

Set Status Readback Location Type

0

Invalid location (Default)

Sets the status location type to the specified value.

1

Use currently selected location

The 5 value for Cartridge may be specified, but since your printer

2

All locations

does not support font cards or cartridges, the command is ignored.

3

Internal (resident)

The 7 value for User-installable flash is only valid when flash

4

Downloaded entity

5

Cartridge

memory is installed.

7

User-installable flash

The 200 value is only valid when a hard disk is installed.

200

Disk

 

 

 

 

ESC*s#U

 

Set Status Readback Location Unit

0

All

Sets the status location unit to the specified value.

1

If download, temporary; otherwise,

The location unit is used along with the location type to identify a

 

highest priority

 

location for the Inquire Status Readback Entity command.

2

If download, permanent; otherwise,

Note: The unit value is interpreted differently, depending on the

 

next higher priority

 

 

location type specified.

 

 

 

ESC*s#I

 

Inquire Status Readback Entity

0

Font

Returns the requested information set by Set Status Readback

1

Macro

Location Type and Set Status Readback Location Unit.

2

User-defined pattern

 

3

Symbol set (for unbound scalable

 

 

fonts)

 

4

Font extended

 

 

 

 

ESC*s1M

 

Free Space

 

 

Returns the total available memory and the largest available block

 

 

of memory.

 

 

 

ESC&r#F

 

Flush All Pages

0

Flush all complete pages

Holds print jobs in the print buffer until the current job finishes

1

Flush all pages

printing.

 

 

 

ESC*s#X

 

Echo

-32767 to 32767

Returns # back to host computer.

Default = 0

 

 

 

 

Page 66
Image 66
Lexmark C760, C762 manual Status Readback