4-43

PostScript

setprintername

string setprintername —

changes the PrinterName system parameter to the value of the string. The string value can be any string up to 32 characters.

This operator is equivalent to executing the following PostScript emulation sequence:

<< /PrinterName (string) >> setsystemparams

Errors: invalidaccess, limitcheck, stackunderflow, typecheck

setquiet

integer setquiet —

changes the user default setting of the PowerSave page device parameter.

The following integers are valid:

0Power Saver Off

1to 120 or 1 to 240 (Model specific)

Number of minutes elapsed after last page prints before

Power Saver is invoked.

Any changes made by this operator are not active until the end of the print job.

Note: Some printer models released in the year 2000 or later designated as Energy Star printers cannot have Power Saver disabled.

This operator is equivalent to executing the following PostScript emulation sequence:

%Go into exitserver or startjob context << /PowerSave integer >> setpagedevice

Errors: rangecheck, stackunderflow, typecheck