4-38

PostScript

setdoret

integer setdoret —

changes the PQET setting for the next page through the end of the print job.

The integer values allowed are:

0turn PQET Off

1turn PQET On

2turn PQET On

3turn PQET On

4turn PQET On

The value you select for PQET returns to the user default setting when the print job is finished.

This operator is equivalent to executing the following PostScript emulation sequence:

<<//PostRenderingEnhanceDetails << /REValue integer >> >>

setpagedevice

Errors: rangecheck, stackunderflow, typecheck

setdostartpage

boolean setdostartpage

sets the DoStartPage system parameter to the value of boolean. The DoStartPage system parameter must be present for the setdostartpage operator to be present. For more information, see “DoStartPage” on page 4-67.

Errors: invalidaccess, stackunderflow, typecheck