Installation

Wrap the insulation material around the connecting portion.

1.Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap.

2.Wrap the area which accommodates the rear piping housing section with vinyl tape.

3.Bundle the piping and drain hose together by wrap- ping them with cloth tape over the range within which they fit into the rear piping housing section.

Reroute the pipings and the drain hose across the back of the chassis.

Set the pipings and the drain hose to the back of the chassis with the tubing holder.

Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be engaged at the bottom of chassis.

Indoor unit installation

1.Remove the spacer.

2.Ensure that the hooks are properly seated on the installation plate by moving it left and right.

3.Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

Plastic bands Insulation material

Connection

Indoor

unit piping

pipe

 

Vinyl tape

Wrap with vinyl tape

(wide)

 

 

Pipe

 

Vinyl tape(narrow)

Connecting cable

 

 

Pipe

Drain hose

Vinyl tape(narrow)

 

 

Wrap with

 

vinyl tape(wide)

Piping for passage through piping hole

Tubing holder

Connecting

cable

Drain hose

Service Manual 19

Page 19
Image 19
LG Electronics AS-W096URH0/UBH0/UWH0/UMH0, AS-W126URH1/UBH1/UWH1/UMH1, AS-W096URH1/UBH1/UWH1/UMH1 Indoor unit installation