Troubleshooting Guide

The problem of missing the connector (INDOOR MAIN PCB ASSY)

Connectors

Condition

Problem (error mode)

 

 

 

 

OPEN

• Malfunctions all indoor & outdoor unit.

CN-AC/DC

• Malfunctions remocon, force, test operation mode.

 

 

 

 

CN-FAN

OPEN

• Malfunctions indoor fan motor.

 

 

 

 

 

• Malfunctions outdoor unit.

CN-T/Block

OPEN

• Stop compressor and outdoor fan motor.

• The operation LED blinks 5 times.

 

 

 

 

• Communication error.

 

 

 

CN-DISP1

OPEN

• Malfunctions remote contoller.

• Don't operate the power display module.

 

 

 

 

 

CN-DISP2

OPEN

• Don't operate the power display module.

 

 

 

CN-TH

OPEN/SHORT

• The operation LED blinks twice.

• Enable to receive remote singnal.

 

 

 

 

 

CN-U/D

OPEN

• Malfunctions UP/DOWN step motor.

• Don't operate louver.

 

 

 

 

 

The problem of missing the connector (OUTDOOR MAIN PCB ASSY)

Connectors

Condition

Problem (error mode)

 

 

 

CN-4 WAY

OPEN

• Malfunctions 4-WAY valve.

 

 

 

CN-FAN

OPEN

• Malfunctions fan

 

 

 

CN-TH

OPEN/SHORT

• The operation LED blinks twice.

• The LED01M blinks twice.

 

 

 

 

 

 

 

• The LED01M blinks 10 times.

CN-D-PIPE

OPEN/SHORT

• Continue Comp. operation.

(when the discharge pipe TH opens)

 

 

• Stop Comp. operation

 

 

(when the discharge pipe TH shorts)

 

 

 

CN-UVW

OPEN

• Stop compressor.

 

 

 

Service Manual 79

Page 79
Image 79
LG Electronics AS-W096URH0/UBH0/UWH0/UMH0 service manual Problem of missing the connector Indoor Main PCB Assy, CN-T/Block