LG Electronics AS-W126URH1/UBH1/UWH1/UMH1 service manual When indoor Fan does not operate

Models: AS-W096URH1/UBH1/UWH1/UMH1 AS-W126URH1/UBH1/UWH1/UMH1 AS-W096URH0/UBH0/UWH0/UMH0 AS-W126URH0/UBH0/UWH0/UMH0/UCH0

1 84
Download 84 pages 60.42 Kb
Page 72
Image 72

Troubleshooting Guide

Trouble 4

When indoor Fan does not operate.

 

 

 

 

 

Turn off main power.

 

 

 

Check the connection of CN-MOTOR.

Check the Fan Motor.

Check the Fuse(AC250V, T2A).

Check the related circuit of indoor Fan Motor.

The pin No.45 of micom and the part for driving SSR.

Check the related pattern.

Check the SSR.

-SSR Open: Indoor Fan Motor never operate.

-SSR short: Indoor Fan Motor always operates in case of ON or OFF.

Turn on the main power

Check the SSR high speed operation by remote control.

(the Indoor Fan Motor is connected)

The voltage of Pin No 1(orange) and 3(black) of CN-MOTOR.

About AC 180V over

About AC 50V over

SSR is not damaged

Check SSR

72Room Air Conditioner

Page 72
Image 72