LG Electronics AS-W126URH0/UBH0/UWH0/UMH0/UCH0, AS-W126URH1/UBH1/UWH1/UMH1 service manual

Models: AS-W096URH1/UBH1/UWH1/UMH1 AS-W126URH1/UBH1/UWH1/UMH1 AS-W096URH0/UBH0/UWH0/UMH0 AS-W126URH0/UBH0/UWH0/UMH0/UCH0

1 84
Download 84 pages 60.42 Kb
Page 73
Image 73

Troubleshooting Guide

Trouble 5 When the horizontal louver does not operate.

• Confirm that the vertical louver is normally geared with the shaft of Stepping Motor.

• If the regular torque is detected when rotating the vertical louver with hands Normal

Check the connecting condition of CN-U/D Connector

Check the soldering condition(on PCB) of CN-U/D Connector

Check the operating circuit of the vertical louver

Confirm that there is DC +12V between pin of CN-U/D and GND.

Confirm that there is a soldering short at following terminals. - Between 41 , 42 , 43 and 44 of MICOM

- Between 4 , 5 , 6

and 7 of IC01M

- Between 10 , 11 , 12

and 13 of IC01M

If there are no problems after above checks.

Confirm the assembly condition that are catching and interfering parts in the link of the vertical louver

Service Manual 73

Page 73
Image 73
LG Electronics AS-W126URH0/UBH0/UWH0/UMH0/UCH0 service manual Trouble 5 When the horizontal louver does not operate