Troubleshooting Guide

Trouble 8-2When compressor does not oprate normally.

Communication error between Indoor and Outdoor (Error Code )

Does the operating LED in display PCB Ass'y blink 5 times?

YES

Is the voltage of BR/BK, RD AC220/240V in Main PCB Ass'y.

YES

Is the connection of CN-T/Block and in CN-AC/DC indoor P.C.B Ass'y is right?

YES

Replace the PCB Ass'y.

Main PCB Ass'y (Indoor/Outdoor)

Control Box Ass'y.

NO

NO

NO

Check the state of connecting cable (3 line) bewteen indoor and outdoor unit .

Check Fuse, Noise Filter, PTC, etc.

Electrical wiring diagram(Colors)

Check the connecting state

of connectors in outdoor PCB Ass'y

Check the Fuse of outdoor PCB Ass'y.

Reconnect the connectors.

Check the PCB pattern(Resoldering).

Service Manual 77

Page 77
Image 77
LG Electronics AS-W126URH0/UBH0/UWH0/UMH0/UCH0 service manual Trouble 8-2When compressor does not oprate normally