Operation

Auto restartingoperation

When the power is restarted after a sudden power failure while in appliance operation, the mode before the power failure is kept on the memory and the appliance automatically operates in the mode on the memory.

Operation mode that is kept on the memory

-State of operation ON/OFF

-Operation mode/setting temp./selected airflow speed

-Sleep timer mode/remaining time of sleep timer

-Chaos Swing

Forced operation

To operate the appliance by force in case that the remote control is lost, the forced operation selection switch is on the main unit of the appliance to operate the appliance in the standard conditions.

The operation condition is set according to the outdoor temp. and intake air temperature as follows.

Indoor temp.

Operating Mode

Setting temp.

Setting speed of

indoor fan

 

 

 

 

 

 

 

over 24°C

Cooling

22°C

 

 

 

 

High speed

21~24°C

Healthy Dehumidification

23°C

 

 

 

 

below 21°C

Heating

24°C

 

 

 

 

 

The unit select before operating mode in 3 hours.

TrialOperation

Press the Tact Switch for compulsory operation of the main body for 3 seconds in order to operate in the trial operation mode.

-Operation mode: Cold

-Indoor pan: Strong wind

-COMP frequency: Step 5

-COMP compulsorily operates for about 18 minutes irrespective of indoor temperature.