Operation
Jet coolmodeoperation
•While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the other mode operation(cooling, dehumidification, ventilation), the Jet Cool mode is operated.
•In the Jet Cool mode, the indoor fan is operated
•In the Jet Cool mode, the room temperature is controlled to the setting temperature, 18°C.
•When the sleep timer mode input while the Jet Cool mode operation, the Jet Cool mode has the priority.
•When the Jet Cool key is input, the upper/lower vane is reset to those of the initial cooling mode and then operated in order that the air outflow could reach further.
Jet heatmodeoperation
•While in cooling mode or Fuzzy operation, the Jet Heat key cannot be input. When it is input while in the Heating mode operation (dehumidification), the Jet Heat mode is operated.
•In the Jet Heat mode, the indoor fan is operated
•In the Jet Heat mode, the room temperature is controlled to the setting temperature, 30°C.
•When the sleep timer mode input while the Jet Heat mode operation, the Jet Heat mode has the priority.
•When the Jet Heat key is input, the upper/lower vane is reset to those of the initial Jet heating mode and then operated in order that the air outflow could reach under flow.
Swingmode
1.Chaos swing mode
•By the Chaos swing key input, the upper/lower vane automatically operates with the Chaos swing or it is fixed to the desired direction.
CLOSED |
| |
| Chaos Swing On | |
Mode 9 |
| |
Mode 8 |
| |
Mode 7 |
| |
Mode 6 |
| |
Mode 5 |
| |
Mode 4 |
| |
Mode 3 |
| |
Chaos Swing Mode 2 |
| |
Mode 1 | The first path | |
OPEN | ||
|