Operation

Auto Cleaning

Function used to perform the Self Cleaning to prevent the Unit from Fungus and Bad Odors.

Used after the Shut Down of Cooling Operation to Clean the Evaporator and keep it as fresh for the Next operation.

During Self Cleaning the Outdoor Unit is Switched off.

The function is easy to be operated as It is accessed through the Remote Controller.

1) Heat/pump Model

 

 

 

 

2) Cooling/only Model

 

ON

 

OFF

 

 

 

ON

 

OFF

 

Cooling CYCLE

Fan

Heating

Fan

 

Cooling CYCLE

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comp.

 

13 Min

60 Sec

120 Sec

Comp.

 

30 Min

ON

OFF

ON

OFF

ON

OFF

 

 

Indoor Fan

Setting Step

Low

Low

Low

Indoor Fan

Setting Step

Low

Auto Changeover(Optional)

While in fuzzy mode operation the air condi- tioner changes the operation mode automati- cally to keep indoor temperature.

When room temperature vary over ±2°C with respect to setting temperature, air condition- er keeps the room temperature in ±2°C with respect to setting temperature by auto change mode.

 

 

 

 

 

 

Outdoor

 

 

 

 

 

 

temp.

 

 

 

 

 

 

 

 

 

 

Outdoor temp.

 

 

 

 

 

 

 

+2° C

 

 

Indoor temp.

 

 

 

 

 

 

 

 

 

 

 

 

+1° C

 

 

 

 

 

 

+0.5° C

 

 

 

 

 

 

Set Temp.

 

 

 

 

 

 

 

 

 

 

 

 

-0.5°C

 

 

 

 

 

 

 

 

 

 

 

 

-1°C

 

 

 

 

 

 

 

 

 

 

 

 

-2°C

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto

 

 

 

 

 

 

Change

 

COOLING

 

HEATING

COOLING

Mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

30° C

20° C

10° C

LowAmbient

If outdoor temperature drops below certain temperature,liquid back is prevented by reducing fan speed. It can prevent frosting of evaporator and keep cooling operation

No matter even if the outdoor temperature reaches -10°C.

You can Cool your room at your desired temperature all your around.

 

 

 

Comp Freq.

Freq.

 

 

 

 

 

 

Outdoor fan

On

On

 

Outdoor pipe temp.

 

 

 

0° C° outdoor fan On/Off

Off

Off

 

control

 

- 0

° °

Outdoor temp.

 

C

 

 

25

 

 

 

 

 

20

Cond . temp.

 

Outdoor temp.:-10°C

 

 

 

 

 

 

 

15

 

 

 

 

°C)

10

 

 

 

 

Temp.(

 

 

 

 

5

Outdoor fan On/Off

control

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

0

50

100

150

200

 

-5

 

 

Time(Min.)

 

 

 

 

 

 

46Room Air Conditioner

Page 46
Image 46
LG Electronics AS-W096URH1/UBH1/UWH1/UMH1, AS-W126URH1/UBH1/UWH1/UMH1 Auto Cleaning, Auto ChangeoverOptional, Low Ambient