LG Electronics AS-W126URH0/UBH0/UWH0/UMH0/UCH0, AS-W126URH1/UBH1/UWH1/UMH1 Sleep timer operation

Models: AS-W096URH1/UBH1/UWH1/UMH1 AS-W126URH1/UBH1/UWH1/UMH1 AS-W096URH0/UBH0/UWH0/UMH0 AS-W126URH0/UBH0/UWH0/UMH0/UCH0

1 84
Download 84 pages 60.42 Kb
Page 41
Image 41

Operation

Sleep timer operation

When the sleep time is reached after [1,2,3,4,5,6,7hr] is input by the remote control during the operation, the operation of the appliance stops.

When the appliance is on pause, the sleep timer mode cannot be input.

1.Sleep timer operation for cooling cycle

While in cooling mode operation, 30 min. later since the start of the sleep timer, the setting temperature increase by 1°C. After another 30min. elapse, it increases by 1°C again.

Setting temp. (˚C)

Cooling ON temp. (Setting temp. +0.5˚C)

Cooling OFF temp. (Setting temp. -0.5˚C)

1.0˚C up

1.0˚C up

0.51 Sleep time (hr)

2.Sleep timer operation for heating cycle

While in heating mode operation, 60 min. later since the start of the sleep timer, the setting temperature decrease by 1°C. After another 60min. elapse, it decreases by 1°C again.

Setting temp. (° C)

Heating OFF temp. (Setting temp. +3.0° C)

Heating ON temp. (Setting temp)

1.0° C down

1.0° C down

1

2

Sleep time (hr)

Service Manual 41

Page 41
Image 41
LG Electronics AS-W126URH0/UBH0/UWH0/UMH0/UCH0, AS-W126URH1/UBH1/UWH1/UMH1 Sleep timer operation for cooling cycle