2.Fuzzy operation for Heating

According to the setting temperature selected by Fuzzy rule, the operating frequency of compressor is deter- mined like heating mode operation.

At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temperature at that time.

When the Fuzzy key(=setting temp. key) is input after the initial setting temperature is selected, the Fuzzy key value and intake air temperature at that time are compared to select the setting temperature automatical- ly according to the Fuzzy rule.

While in Fuzzy operation, the airflow speed of the indoor fan is automatically operated by Fuzzy logic.

 

Intake Air temp.

Setting temp.

Fan speed

 

 

 

 

at beginning

over 20°C

intake air temp. +0.5°C

 

 

 

 

below -20°C

20°C

 

 

 

 

 

 

Fuzzy airflow

 

16~30°C

Fuzzy rule

during opertion

 

 

 

below 16°C

16°C Fuzzy rule

 

 

 

 

 

 

over 30°C

30°C Fuzzy rule

 

 

 

 

 

3.Fuzzy operation for dehumidification

At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temperature at that time.

According to the setting temperature selected by Fuzzy rule, the operating frequency of compressor is deter- mined like dehumidefication mode operation.

 

Intake Air temp.

Setting temp.

Fan speed

 

 

 

 

 

over 26°C

25°C

 

at beginning

 

 

 

18~26°C

intake air temp. -0.5°C

 

 

 

 

 

 

below 18°C

18°C

Fuzzy airflow

 

 

 

 

18~30°C

Fuzzy rule

 

 

during operation

 

 

 

below 18°C

18°C Fuzzy rule

 

 

 

 

 

 

over 30°C

30°C Fuzzy rule

 

 

 

 

 