Functions
Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
•Room temperature sensor. (Thermistor)
•Pipe temperature sensor. (Thermistor)
Room temperature control
• Maintain the room temperature in accordance with the Setting Temp.
Starting the Current Control
• Indoor fan is delayed for 5 sec at the starting.
Time Delay Safety Control
•Restarting is for approx. 2 minutes.
Indoor Fan Speed Control
•Super High, High, Med, Low
Operation indication Lamps (LED)
Soft Dry Operation Mode
• Intermittent Operation of fan at low speed or off.
Sleep Mode Auto Control
•The fan is switched to low(Cooling), low(Heating) speed.
•The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Natural Air Control by CHAOS Logic
•The fan is switched to intermittent or irregular operation
•The fan speed is automatically switched from high to low speed.
Airflow Direction Control
•The louver can be set at the desired position or swing up and down automatically.
Auto Changeover
Horizontal airflow Direction Control(Optional)
AUTO CLEAN(Optional)
PLASMA
•The function will be operated while in any operation mode with selecting the function.
•The function is to be stopped while it is operating with selecting the function.
Defrost(Deice) control (Heating)
•Both the indoor and outdoor fan stops during defrosting.
•The indoor fan stops until the evaporator pipe temperature will be reached at 34°C.
Heater (Optional)
30Room Air Conditioner