HealthyDehumidificationmodeoperation

When the dehumidification operation is set by the remote controller the intake air temperature is detected and the setting temp. is automatically set according to the intake air temperature.

Intake air Temp.

Setting Temp.

 

 

26°C intake air temp.

25°C

 

 

24°C intake air temp.< 26°C

intake air temp. -1°C

 

 

18°C < intake air temp. < 24°C

intake air temp. -0.5°C

 

 

intake air temp. 18°C

18°C

 

 

When intake air temp reaches above the temp of setting +1.0°C, condition of compressor same as cooling mode operation.

When intake air temperature reaches bolow the temp of setting –1.0°C, compressor operate step1~step3 and indoor fan speed repeatly operate low or stop.