Troubleshooting Guide

Trouble 8-3When compressor does not oprate normally.

CT Error (Error Code )

Does the operating LED in Display PCB Ass'y blink 7 times?

YES

Is the courrent transformer(CT) in Main PCB Ass'y right?

YES

NO

Check the state of connecting cable (3 line) bewteen Indoor and Outdoor Unit .

Check fuse, Noise Filter, PTC, etc.

NO

Check the PCB pattern(resoldering)

NO

Is the indoor/outdoor fan locked?

YES

Is the discharge temperature of Indoor unit right(11°C~17°C) in the cooling mode?

YES

Is the refrigerant pressure right?

YES

Replace the PCB Ass'y.

Main PCB Ass'y(Outdoor)

Control Box Ass'y(Outdoor)

Check the indoor/outdoor fan motor.

NO

Check the compressor.

NO

Supply the refrigerant or Discharge the refrigerant.

78Room Air Conditioner

Page 78
Image 78
LG Electronics AS-W096URH1/UBH1/UWH1/UMH1 Trouble 8-3When compressor does not oprate normally, CT Error Error Code ➆