TOC

TOC

A-7

 

 

A-7

 

 

INSTALLATION

 

ELECTRICAL OUTPUT

 

 

 

 

 

 

 

CAUTION

 

 

CONNECTIONS

 

 

 

 

 

 

 

 

Return to Section

Section TOC

See Figure A.2 for the location of the 115V DC volt receptacle, weld output terminals, and ground stud.

WELDING CABLE CONNECTIONS

CABLE INSTALLATION AND CABLE SIZES

With the engine off, route the electrode and work cables through the strain relief bracket on the base and connect to the terminals located below the fuel tank mounting rail. (See size recommendations below.) For positive polarity, connect the electrode cable to the ter- minal marked Positive (+). For Negative polarity, con- nect the electrode cable to the Negative (-) terminal. These connections should be checked periodically and tightened if necessary.

Loose connections will cause the output terminals to overheat. The terminals may eventually melt.

Do not cross the welding cables at the output termi- nal connection. Keep the cables isolated and sepa- rate from one another.

When welding at a considerable distance from the welder, be sure you use ample size welding cables. Table A.1 lists recommended cable sizes and lengths for rated current and duty cycle. Length refers to the distance from the welder to the work and back to the welder. Cable diameters are increased for long cable lengths to reduce voltage drops.

Lincoln Electric offers a welding accessory kit with the properly specified welding cables. See the Accessories section of this manual for more information.

Return to

Return to

AUXILIARY POWER RECEPTACLE,

PLUGS, AND HAND-HELD EQUIPMENT

The DC auxiliary power, supplied as a standard, has a rating of 1.75 kw of 120V DC.

FIGURE A.2 - CLASSIC I OUTPUT CONNECTIONS

Return to Section TOC

Return to Master TOC

1

2

4

3

1.120 VOLT DC RECEPTACLE

2.WELD OUTPUT TERMINALS (2)

3.GROUND STUD (LOCATION)

4.CABLE STRAIN RELIEF BRACKET

Return to Section TOC

Return to Master TOC

TABLE A.1 - RECOMMENDED COPPER WELDING CABLE SIZE AND LENGTH

TOTAL COMBINED LENGTH OF ELECTRODE AND WORK CABLES

 

 

Cable size for combined length of

 

 

electrode plus work cable

 

 

 

 

Amps

Duty Cycle

Up to 200 ft.

200 to 250 ft.

200

60%

1

1/0

 

 

 

 

CLASSIC I

Page 13
Image 13
Lincoln Electric SVM134-A Electrical Output Connections, Welding Cable Connections, Cable size for combined length