F-7

 

 

 

 

F-7

TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

 

 

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

The engine starts and runs at the

 

1. Check the DC receptacle and

1.

Check for loose or faulty con-

correct speed, but there is no DC

 

plug for loose or faulty connec-

 

nections or wires at the 115

auxiliary output voltage at the

 

tions.

 

 

VDC receptacle and associated

115VDC receptacle. The welding

 

2. Check the 15 Amp fuse. CSA

 

circuitry.

See the Wiring

generator is functioning correctly.

 

 

Diagram.

 

 

machines only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The actual welding current is much

 

1. Check the welding cables for

1.

The engine RPM may be low. If

less than is indicated on the dials.

 

loose or faulty connections.

 

necessary perform the Engine

 

 

2. The welding cables may be

 

Throttle Adjustment Test.

 

 

 

 

 

 

 

excessively long or coiled.

2.

Perform the DC Exciter Test.

 

 

3. Check the main DC generator

3.

Check the fine current control

 

 

brushes for good commutation

 

field rheostat for resistance and

 

 

and alignment.

Contact the

 

proper operation. Normal resis-

 

 

Lincoln Electric

Service Dept.

 

tance is 64 ohms. Check asso-

 

 

1-800-833-9353 (WELD).

 

ciated wires for loose or faulty

 

 

 

 

 

connections.

See the Wiring

 

 

 

 

 

Diagram.

 

 

 

 

 

4.

Check the current range selec-

 

 

 

 

 

tor switch and contacts for prop-

 

 

 

 

 

er operation.

 

 

 

 

 

5.

Perform the

Main Generator

 

 

 

 

 

Shunt Field Winding Test.

 

 

 

 

6.

The main armature may be

 

 

 

 

 

faulty. Check for grounds.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.