F-44

F-44

TROUBLESHOOTING & REPAIR

MAIN GENERATOR FRAME REMOVAL

AND REPLACEMENT (continued)

FIGURE F.23 – MAIN GENERATOR FEET MOUNTING

MAIN GENERATOR

FEET (2)

REMOVE MOUNTING

NUTS, WASHERS,

AND BOLTS

30.Using the 3/4” wrench, remove the frame mounting bolts, nuts, and washers from the feet of the main generator. See Figure F.23.

FIGURE F.24 – MAIN GENERATOR ENGINE MOUNTING

SLING

ENGINE / GENERATOR

MOUNTING HOLES

31. With the rope sling around the main genera-

32. Using the 9/16” wrench, remove the bolts

tor frame, carefully lift the frame a small dis-

and lock washers mounting the generator

tance. Slide the wood or steel blocks under

frame to the engine. See Figure F.24.

the engine. See Figure F.24.

 