F-9

 

F-9

TROUBLESHOOTING & REPAIR

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

FUNCTION PROBLEMS

 

The engine will not return to low

1. Make sure the idler control

1. Check the idler control switch

idle when the welding and auxiliary

switch is set to the “Auto” posi-

and associated leads for loose

loads are removed.

tion.

or faulty connections. See the

 

2. Make sure both welding and

Wiring Diagram.

 

 

 

auxiliary loads are removed.

2. Check the reed switch CR2. It

 

3. Check for mechanical restric-

may be stuck closed. Replace if

 

necessary.

 

tions in the idler and throttle link-

 

 

 

age.

3. Perform the Idler Solenoid

 

4. While the engine is running, if

Test.

 

 

 

the oil pressure light is NOT lit,

4. Check for loose or faulty con-

 

the oil pressure switch may be

nections at the idler PC board.

 

faulty. See the Wiring Diagram.

5. The idler PC board may be

 

 

 

 

faulty. Replace.

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.