TROUBLESHOOTING & REPAIR

FLASHING THE FIELDS

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid elec- trical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot- ing assistance before you proceed. Call 1-800-833-9353 (WELD).

DESCRIPTION

This procedure will magnetize the exciter pole pieces. The exciter can then “build-up” when the engine is started.

MATERIALS NEEDED

12-volt battery

Two jumper wires with alligator clips on each end Wiring Diagram

3/8” Wrench

This procedure takes approximately 15 minutes to perform.