F-5

 

 

F-5

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

The engine starts and runs at the

1. Check the welding cables for

1. Check the fine current control

correct speed but there is no, or

loose or faulty connections.

field rheostat for resistance and

very low, welder output. The DC

2. Check for loose or missing

proper operation. Normal resis-

auxiliary output voltage is normal.

tance is 64 ohms. Check asso-

brushes in the welding genera-

 

ciated wires for loose or faulty

 

tor.

 

connections.

See the Wiring

 

 

 

 

Diagram.

 

 

 

 

2. Perform the Main Generator

 

 

Shunt Field Winding Test.

 

 

3. Check the continuity of the inter-

 

 

pole coils. They should show

 

 

continuity from the positive

 

 

brusholders to the positive out-

 

 

put terminal and should NOT be

 

 

grounded to

the generator

 

 

frame.

 

 

 

 

4. Check the continuity of the

 

 

series coils. They should show

 

 

continuity from the negative

 

 

brusholders, through the current

 

 

selector switch, to the negative

 

 

output terminal and should NOT

 

 

be grounded to the generator

 

 

frame.

 

 

 

 

5. The main armature may be

 

 

faulty. Check for grounds and/

 

 

or shorts.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.