F-10

TROUBLESHOOTING & REPAIR

F-10

 

 

 

Observe Safety Guidelines

 

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

The engine will NOT go to high

1.

Check welding cables for loose

1. Check the reed switch (CR2) for

 

speed when a load is applied to the

 

or faulty connections.

 

proper operation. The

reed

 

welding output terminals.

The

 

 

 

switch should close when there

 

engine does go to high speed when

 

 

 

is current flow in the welding cir-

 

a load is applied to the DC auxiliary

 

 

 

cuit.

 

 

power receptacle.

 

 

 

2. Locate the red lead connected

 

 

 

 

 

 

 

 

 

 

 

to the idler PC board. While

 

 

 

 

 

 

leaving the red lead connected,

 

 

 

 

 

 

jumper the red lead to frame

 

 

 

 

 

 

ground. If the engine goes to

 

 

 

 

 

 

high speed, the fault is in the

 

 

 

 

 

 

reed switch or associated leads.

 

 

 

 

 

 

See the Wiring Diagram.

 

 

 

 

 

 

3. If the engine does NOT go to

 

 

 

 

 

 

high speed (in step 2), the idler

 

 

 

 

 

 

PC board may be faulty.

 

 

 

 

 

 

 

 

The engine will NOT go to high

1.

Check the auxiliary power plug

1.

Check the black “B” leads con

-

speed when a load is applied to the

 

and associated leads for loose

 

nected to the idler PC board and

 

DC auxiliary receptacle.

The

 

or faulty connections.

 

associated connections.

See

 

engine does go to high speed when

2. The load may be too small. The

 

the Wiring Diagram.

 

 

a load is applied to the welding out-

 

 

 

 

 

load must be above 150 watts.

2.

The idler PC board may be

 

put terminals.

 

 

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

CLASSIC I

Page 54