Lincoln Electric SVM136-A service manual Installation, Return to Section TOC, Return to Master TOC

Models: SVM136-A

1 102
Download 102 pages 56.21 Kb
Page 13
Image 13
FIGURE A.5

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-7

A-7

INSTALLATION

FIGURE A.5

OUTPUT TERMINAL CONNECTIONS

1

2

TABLE A.1 - CABLE SIZES FOR COMBINED LENGTH- +OF ELECTRODE AND WORK CABLE

1.NEGATIVE (-) WELDING CABLE CONNECTION

2.POSITIVE (+) WELDING CABLE CONNECTION

TABLE A.1 - CABLE SIZES FOR COMBINED LENGTH

OF ELECTRODE AND WORK CABLE

 

MACHINE LOAD

 

400A

500A

 

(100% DUTY

(50% DUTY

CABLE LENGTHS

CYCLE)

CYCLE)

 

 

 

UP TO 50 ft

3/0

2/0

(15 m)

85 mm2

67 mm2

 

 

 

50 to 100 ft

3/0

2/0

(15 to 30 m)

85 mm2

67 mm2

 

 

 

100 to 150 ft

3/0

3/0

(30 to 46 m)

85 mm2

85 mm2

 

 

 

150 to 200 ft

3/0

3/0

(46 to 61 m)

85 mm2

85 mm2

 

 

 

200 to 250 ft

4/0

4/0

(67 to 76 m)

107 mm2

107 mm2

 

 

 

IDEALARC CV-400

Page 13
Image 13
Lincoln Electric SVM136-A service manual Installation, Return to Section TOC Return to Section TOC Return to Section TOC