Lincoln Electric SVM136-A MAIN TRANSFORMER T1 VOLTAGE TEST, Troubleshooting & Repair

Models: SVM136-A

1 102
Download 102 pages 56.21 Kb
Page 56
Image 56
MAIN TRANSFORMER (T1) VOLTAGE TEST

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-16

F-16

TROUBLESHOOTING & REPAIR

MAIN TRANSFORMER (T1) VOLTAGE TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid elec- trical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot- ing assistance before you proceed. Call 216-383-2531 or 1-800-833-9353 (WELD).

DESCRIPTION

This test will determine if the correct voltages are being applied to the primary windings of the Main Transformer (T1) and induced on the secondary winding, auxiliary windings, and phase angle windings.

MATERIALS NEEDED

Volt/ohmmeter (Multimeter) 5/16” Nut driver

IDEALARC CV-400 wiring diagram (See the Electrical Diagrams section of manual.)

IDEALARC CV-400

Page 56
Image 56
Lincoln Electric SVM136-A service manual MAIN TRANSFORMER T1 VOLTAGE TEST, Troubleshooting & Repair, Return to Section TOC