TYPICAL OUTPUT VOLTAGE WAVEFORM – MACHINE LOADED

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-29

F-29

TROUBLESHOOTING & REPAIR

TYPICAL OUTPUT VOLTAGE WAVEFORM – MACHINE LOADED

CH1

0 volts

20 volts

5 ms

This is the typical DC open circuit voltage waveform generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal divi- sion represents 5 milliseconds in time. The machine was loaded with a resistance grid bank. The CV-400 meters read 400 amps at 36 VDC.

Note: Scope probes connected at

machine output terminals: (+) probe to positive terminal, (-) probe to neg- ative terminal.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

IDEALARC CV-400