C-5

C-5

ACCESSORIES

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

5.Extend wire feeder control cable lead #21 so it can be connected directly to the work piece.

a.Make a bolted connection using AWG #14 or larg- er insulated wire. Tape the bolted connection with insulating tape.

b.An S-16586- X remote voltage sensing work lead is available for this purpose.

c.Keep the #21 lead electrically separate from the work cable circuit and connection.

d.Tape the #21 lead to the work cable for ease of use.

6.Connect NA-5 wire feeder control jumpers on Voltage Control Board. See the NA-5 operator's manual.

NOTE: For proper NA-5 operation, the electrode cables must be secured under the clamp bar on the left side of the NA-5 Control Box.

NOTE: The connection diagram shown in Figure C.3 shows the electrode connected for positive polarity. To change polarity:

a. Set the CV-400 POWER toggle switch to the OFF (0) position.

b. Move the electrode cable to the negative (-) output terminal.

c. Move the work cable to the positive (+) output termi- nal.

d. Set the VOLTMETER toggle switch to negative (-).

e. See NA-5manual for changing welding polarity.

Return to Section TOC

Return to Master TOC

IDEALARC CV-400

Page 27
Image 27
Lincoln Electric SVM136-A service manual Accessories