TROUBLESHOOTING & REPAIR

 

 

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

The machine has high welding out-

1.

If remote control is being used,

1.

Check the Output Control switch

 

put and no control.

 

set the Output Control Switch

 

(S2) and associated wiring. See

 

 

 

(S2) to the “Machine or Local”

 

the Wiring Diagram.

 

 

 

position and control the weld

2. Check feedback

leads #220,

 

 

 

output with the machine Output

 

 

 

 

#204, #205 and #206 for loose

 

 

 

Control (R4). If the problem is

 

 

 

 

 

or faulty connections.

 

 

 

solved, check the remote con-

 

 

 

 

 

 

 

 

 

 

 

 

trol unit or wire feeder and asso-

3.

Perform

the

SCR/Diode

 

 

 

ciated control cable.

 

Rectifier Bridge Test.

 

 

2. Check the remote control leads

4. The control board may be

 

 

 

for “grounds” to the negative

 

faulty. Replace.

 

 

 

 

 

welding output. If leads #75,

 

 

 

 

 

 

 

 

#76 or #77 are “grounded” to the

 

 

 

 

 

 

 

 

negative welding output, the

 

 

 

 

 

 

 

 

machine output may go very

 

 

 

 

 

 

 

 

high without control.

 

 

 

 

 

 

 

 

 

 

 

 

The machine has minimum (or very

1.

If remote control is being used,

1.

Check the Output Control (R4)

 

low) welding output and no control.

 

set the Output Control Switch

 

and associated wiring. See the

 

 

 

(S2) to the “Machine or Local”

 

Wiring Diagram.

 

 

 

 

 

position and control the weld

2. Check the Output Control switch

 

 

 

output with the machine Output

 

 

 

 

(S2) and associated wiring. See

 

 

 

Control (R4). If the problem is

 

 

 

 

 

the Wiring Diagram.

 

 

 

solved, check the remote con-

 

 

 

 

 

 

 

 

 

 

 

 

trol unit or wire feeder and asso-

3.

Perform the Main Transformer

 

 

 

ciated control cable.

 

Test.

 

 

 

 

 

2.

Make certain the remote control

4.

Perform the SCR/Diode Rectif-

 

 

 

leads (#75, #76, #77) are not

 

ier Bridge Test.

 

 

 

 

 

grounded to the positive welding

5. The control board may be faulty.

 

 

 

output.

 

 

 

 

 

 

 

 

 

 

3. Make certain the three-phase

 

 

 

 

 

 

 

 

input voltage is correct and

 

 

 

 

 

 

 

 

matches the machine rating and

 

 

 

 

 

 

 

 

the reconnect panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

IDEALARC CV-400

Page 46
Image 46
Lincoln Electric SVM136-A service manual SCR/Diode