| TROUBLESHOOTING & REPAIR |
|
|
| ||||
| Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE | ||||
| detailed in the beginning of this manual. |
|
|
|
|
| ||
|
|
|
| |||||
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | |||||
| (SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |||||
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
| The machine has high welding out- | 1. | If remote control is being used, | 1. | Check the Output Control switch | |||
| put and no control. |
| set the Output Control Switch |
| (S2) and associated wiring. See | |||
|
|
| (S2) to the “Machine or Local” |
| the Wiring Diagram. | |||
|
|
| position and control the weld | 2. Check feedback | leads #220, | |||
|
|
| output with the machine Output | |||||
|
|
|
| #204, #205 and #206 for loose | ||||
|
|
| Control (R4). If the problem is |
| ||||
|
|
|
| or faulty connections. | ||||
|
|
| solved, check the remote con- |
| ||||
|
|
|
|
|
|
|
| |
|
|
| trol unit or wire feeder and asso- | 3. | Perform | the | SCR/Diode | |
|
|
| ciated control cable. |
| Rectifier Bridge Test. | |||
|
| 2. Check the remote control leads | 4. The control board may be | |||||
|
|
| for “grounds” to the negative |
| faulty. Replace. |
|
| |
|
|
| welding output. If leads #75, |
|
|
|
|
|
|
|
| #76 or #77 are “grounded” to the |
|
|
|
|
|
|
|
| negative welding output, the |
|
|
|
|
|
|
|
| machine output may go very |
|
|
|
|
|
|
|
| high without control. |
|
|
|
|
|
|
|
|
|
|
| |||
| The machine has minimum (or very | 1. | If remote control is being used, | 1. | Check the Output Control (R4) | |||
| low) welding output and no control. |
| set the Output Control Switch |
| and associated wiring. See the | |||
|
|
| (S2) to the “Machine or Local” |
| Wiring Diagram. |
|
| |
|
|
| position and control the weld | 2. Check the Output Control switch | ||||
|
|
| output with the machine Output | |||||
|
|
|
| (S2) and associated wiring. See | ||||
|
|
| Control (R4). If the problem is |
| ||||
|
|
|
| the Wiring Diagram. | ||||
|
|
| solved, check the remote con- |
| ||||
|
|
|
|
|
|
|
| |
|
|
| trol unit or wire feeder and asso- | 3. | Perform the Main Transformer | |||
|
|
| ciated control cable. |
| Test. |
|
|
|
|
| 2. | Make certain the remote control | 4. | Perform the SCR/Diode Rectif- | |||
|
|
| leads (#75, #76, #77) are not |
| ier Bridge Test. |
|
| |
|
|
| grounded to the positive welding | 5. The control board may be faulty. | ||||
|
|
| output. | |||||
|
|
|
|
|
|
|
| |
|
| 3. Make certain the |
|
|
|
|
| |
|
|
| input voltage is correct and |
|
|
|
|
|
|
|
| matches the machine rating and |
|
|
|
|
|
|
|
| the reconnect panel. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call