Lincoln Electric SVM136-A Automatic Wire Feeders, Accessories, Feederterminal, Section TOC

Models: SVM136-A

1 102
Download 102 pages 56.21 Kb
Page 25
Image 25
Section TOC

C-3

C-3

ACCESSORIES

CONNECTION OF LINCOLN ELECTRIC AUTOMATIC OR SEMIAUTOMATIC WIRE FEEDERS

Return to

WARNING

ELECTRIC SHOCK can kill.

Only qualified personnel should per- form this maintenance.

Turn the input power OFF at the dis- connect switch or fuse box before working on this equipment.

Do not touch electrically hot parts.

Insulate yourself from work and ground.

NOTE: When using a CV-400 with wire feeders, there may be a small spark if the electrode contacts the work or ground within a few seconds after releasing the trig- ger. With some wire feeders, when the electrical inter- lock is in the ON position the arc can restart if the elec- trode touches the work or ground during these few sec- onds. Refer to K828-1 capacitor discharge circuit ear- lier in this section.

The following descriptions show how to connect the wire feeders using the terminal strip.

Return to Section TOC

Return to Master TOC

• Always wear dry insulating gloves.

Auxiliary power for wire feeder operation is available at both a 14-pin amphenol and at terminal strips with screw-type connections located behind the hinged con- trol panel on the front of the machine. The 14-pin amphenol can provide both 115 VAC (pins A and J) and 42 VAC (pins I and K). The terminal strip provides only 115 VAC (terminals 31 and 32). The two circuits are iso- lated, and each is protected by a 10A circuit breaker.

AUTOMATIC WIRE FEEDERS

CONNECTING THE NA-3 TO THE IDEALARC CV-400

1.Set the CV-400 POWER toggle switch to the OFF (0) position.

2.Disconnect main AC input power to the CV-400.

3.Connect the wire feeder control cable leads to the CV-400 terminal strip as shown in Figure C.2.

4.Connect the wire feeder control cable ground lead to

the frame terminal marked Master TOC .

NOTE: The CV-400 must be properly grounded.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

FIGURE C.2

NA-3 WIRE FEEDER CONNECTION TO THE IDEALARC CV-400

NA-3 WIRE

FEEDERTERMINAL

CONTROL

CABLESTRIPS

TO

21

 

AUTOMATIC

 

CONTROL

4

 

BOX

 

 

 

GND

2

 

21

BLANK

 

4

31

 

2

32

 

31

 

 

32

75

 

 

 

75

76

 

77

 

76

 

 

 

77

 

 

 

-

+

 

NEGATIVE

POSITIVE

 

 

ELECTRODE

 

TO

CABLE TO

 

AUTOMATIC

 

WORK

 

EQUIPMENT

 

 

IDEALARC CV-400

Page 25
Image 25
Lincoln Electric SVM136-A Automatic Wire Feeders, Accessories, Feederterminal, Section TOC, Master TOC, Return to