Lincoln Electric SVM136-A service manual Troubleshooting & Repair, INPUT CONTACTOR TEST continued

Models: SVM136-A

1 102
Download 102 pages 56.21 Kb
Page 55
Image 55
FIGURE F.4 – INPUT CONTACTOR TEST CONNECTIONS

Return to Section TOC

Return to Master TOC

F-15

F-15

TROUBLESHOOTING & REPAIR

INPUT CONTACTOR TEST (continued)

FIGURE F.4 – INPUT CONTACTOR TEST CONNECTIONS

Return to Section TOC

Return to Master TOC

X1, #232

 

 

 

 

 

UVW

(L1)(L2)(L3)

AH# ACC730 - 8025B (3186-30J755 18H)

LINCOLN ELECTRIC CO.

CRI SA M - 12161 - 61

LR495980597

#233

 

 

 

APPLY EXTERNAL 120 VAC HERE (X1, #232 AND #233

LEAD TERMINALS)

UVW

(L1)(L2)(L3)

AH# ACC730 - 8025B

(3186-30J755 18H)

LINCOLN ELECTRIC CO.

CRI SA M - 12161 - 61

LR495980597

Return to Section TOC

Return to Master TOC

TEST FOR CONTACT CONTINUITY

1.Disconnect the main input supply power to the machine.

2.Remove the two leads connected to the input con- tactor coil, #233 and X1/#232. See Figure F.4 for location.

3.Using the external 120VAC supply, apply 120VAC to the terminals of the input contactor coil. If the con- tactor does NOT activate, the input contactor is faulty. Replace the input contactor.

4.With the contactor activated, check the continuity across the contacts. (Zero ohms or very low resis- tance is normal.) See Figure F.4. If the resistance is high, the input contactor is faulty. Replace the input contactor.

5.When the contactor is NOT activated, the resistance should be infinite or very high across the contacts. If the resistance is low, the input contactor is faulty. Replace the input contactor.

Return to Section TOC

Return to Master TOC

IDEALARC CV-400

Page 55
Image 55
Lincoln Electric SVM136-A service manual Troubleshooting & Repair, INPUT CONTACTOR TEST continued, Return to Section TOC