F-30

F-30

TROUBLESHOOTING & REPAIR

TYPICAL SCR GATE VOLTAGE WAVEFORM

MAXIMUM OUTPUT SETTING – NO LOAD

 

CH1

 

0 volts

2 volts

5 ms

This is the typical SCR gate pulse voltage waveform. The machine was in an open circuit condition (no load) and operating properly. Note that each vertical division represents 2 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at

SCR gate and cathode: (+) probe to gate, (-) probe to cathode.

SCOPE SETTINGS

Volts/Div

2V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

IDEALARC CV-400

Page 70
Image 70
Lincoln Electric SVM136-A service manual Typical SCR Gate Voltage Waveform, Maximum Output Setting no Load