FIGURE F.30 – PRIMARY THERMOSTAT LOCATION

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-51

F-51

TROUBLESHOOTING & REPAIR

MAIN TRANSFORMER REMOVAL & REPLACEMENT (continued)

FIGURE F.30 – PRIMARY THERMOSTAT LOCATION

TOP VIEW

FIGURE F.31 – SECONDARY LEAD TRIM AND WELD DETAIL THERMOSTAT

INSULATION

FRONT VIEW

TOC

TOC

10.Mount the primary thermostat to the lead end coil nose. See Figure F.30. Place a small amount of Lincoln Electric E1603 Epoxy between the coil nose and the coil insulation and between the insulation and the thermostat. Hold the thermostat in place with E2381 (.375” wide) tape. If nec- essary, after assembly protect the thermo- stat terminals with E2547 terminal boots.

11.If necessary, trim off excess secondary lead stickout and TIG weld the leads together. See Figure F.31.