F-4

 

 

 

 

 

 

F-4

TROUBLESHOOTING & REPAIR

Observe Safety Guidelines

 

 

 

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Major physical or electrical damage

1. Contact your local authorized

1.

Contact the Lincoln Electric

is evident when the sheet metal

Lincoln

Electric

Field Service

 

Service Department, (216) 383-

cover(s) are removed.

Facility for technical assistance.

 

2531 or 1-800-833-9353 (WELD).

 

 

 

Machine is dead - no output - no

1. Make sure the input power

1. Check the input power switch

fan - no pilot light.

switch is ON.

 

 

 

(S1) for proper operation. See

 

2. Check the three-phase input

 

the Wiring Diagram.

 

 

 

 

voltage at the machine.

Input

2.

Check the leads associated with

 

voltage must match the rating

 

the power switch (S1) and the

 

plate and the reconnect panel.

 

control transformer (T2) for

 

3. Check

for

blown or missing

 

loose or faulty connections. See

 

 

the Wiring Diagram.

 

fuses

in

the

input

lines.

 

 

 

 

 

 

 

 

 

 

3.

Perform the Control

 

 

 

 

 

 

 

Transformer Test.

 

 

 

 

 

1. Check the three-phase input

 

 

The machine is dead - no output -

voltage at the machine.

Input

1.

Perform the Input Contactor

no fan - the pilot light is on.

voltage must match the rating

 

Test.

 

plate and the reconnect panel.

2. Check the associated leads for

 

 

 

 

 

 

 

2. Check for blown or missing

 

loose or faulty connections

 

fuses in the input lines.

 

 

between the input contactor

 

 

 

 

 

 

 

(CR1), the reconnect panel and

 

 

 

 

 

 

 

the main transformer. See the

 

 

 

 

 

 

 

Wiring Diagram.

 

 

 

 

 

 

3. Perform the Main Transformer

 

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.