RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR

If you repair or replace any electrical components.

INPUT IDLE AMPS AND WATTS

Input Volts/Phase/Hertz

Maximum Idle Amps

Maximum Idle KW

200/3/60

10.9

1.2

208/3/60

10.5

1.2

220/3/60

9.9

1.2

230/3/60

9.5

1.2

380/3/60

5.8

1.2

400/3/60

5.5

1.2

415/3/60

5.3

1.2

440/3/60

5.0

1.2

460/3/60

4.8

1.2

500/3/60

4.4

1.2

575/3/60

3.8

1.2

200/3/50

19.8

1.2

220/3/50

18.0

1.2

230/3/50

17.2

1.2

380/3/50

10.4

1.2

400/3/50

9.9

1.2

415/3/50

9.5

1.2

440/3/50

9.0

1.2

500/3/50

7.9

1.2

 

 

 

OPEN CIRCUIT VOLTAGES

Test Points
Input Hertz
Open Circuit Volts

Welding Output Terminals

60

43/47VDC

Welding Ouput Terminals

50

43/47VDC

Auxiliary Output (#31 - #32)

60

114/124VAC

Auxiliary Output (#31 - #32)

50

109/119VAC

Auxiliary Output (#41 - #42)

60

43.8/47.5VAC

Auxiliary Output (#41 - #42)

50

42.0/45.6VAC

Auxiliary Output (#51 - #52)

50

220/231VAC

 

 

 

WELDING OUTPUT LOAD TEST

Output Control Setting

Amps

Volts

 

Minimum

75 to 150

6 to 11

Maximum

525

more than

41.2

 

 

 

 

IDEALARC CV-400

Page 93