2-100
2.2 Preparation
2.2.1 Supported configuration/platform
MINOLTA-QMS magicolor 3100 Diagnostics (Hanabi Service Comma nder) requires the following
configuration:
2.2.2 Installing magicolor 3100 Diagnostics
1) Start Windows.
2) Insert the MINOLTA-QMS magicolor 3100 Diagnostics (Hanabi Service Commander) CD i nto your
CD-ROM Drive.
3) Click the "Start" button on your toolbar.
4) Click "Run."
5) In the dialog box that appears type "x:\commander\setup.exe," and click "OK" (where "x " is the letter of
your CD-ROM drive).
6) Follow the installation instructions that apppear.
2.2.3 Uninstalling magicolor 3100 Diagnostics
1) Start Windows, and click the "Start" button on your toolbar, then click the "Settings" button. Then c lick
on the “Control Panel” button.
2) Double-click the “Add/Remove Programs” icon in the Control Panel window.
3) Select Hanabi Service Commander Vx.xx in the Add/Remove Programs Properties window, and click
the “Add/Remove” button.
4) Shut down and restart your computer.
If you uninstall the system, you will lose any data results from any prior sessions!
2.2.4 Connecting diagnostic tools
1) Remove the magicolor 3100 CONTROLLER BOARD. (See RRP12.3.)
2) Connect the DIAG PWB to the interface connector (P14) of the PWBA HNB MCU.
3) Connect the DIAG PWB to the personal computer with the RS-232C cable.
The RS-232C cable used must be compatible to the DIP SW (cross/straight) setting and
the connector of the DIAG PWB, and also it must be shielded properly and less than 6
ft (2m) in length.
Items Description
CPU Pentium 90 MHz (166 MHz or higher frequencies preferable)
Memory 48 MB (64 MB preferable)
Display VGA (640 × 480)
OS Windows 2000 / Windows Me / Windows 98 / Windows 95
Communication port RS-232C interface (COMM 1 only)