Chapter 1 Troubleshooting
1-57
FIP-18 ADC Sensor Error (ADC Sensor Dustiness Warning)Step Check Yes No
1
Initial check
Check the following for damage.
SENSOR ADC ASSY condition
Replace the parts
concerned Go to step [2]
2Check HARNESS ASSY ADC for continuity
J136 <=> J1361 check continuous? Go to step [3]
Replace
HARNESS ASSY
ADC
3Check HARNESS ASSY FRONT 1A for continuity
J13 <=> P1361 check continuous? Go to step [4]
Replace
HARNESS ASSY
FRONT 1A
4
Check SENSOR ADC ASSY
Check if an error occurs though the SENSOR ADC ASSY
was replaced with a new one.
Replace PWBA
HNB MCU End of work