Chapter 1 Troubleshooting
1-89
FIP-P8 Skewed ImageCondition / initial check
Print skewing
∆ Image is printed in skewed position.
▼ Initial check ▼
Incorrect parts, improper installation, damage, deformation, dirt, foreign su bstance attached, etc.
∇ Major parts to be checked ∇
PAPER FEEDER, CHUTE ASSY REGI, CHUTE ASSY OUT, Transfer Unit (BTR), Imaging Unit (PHD), ROS
ASSY
Item Check Remedy
1Faulty paper setting
Check if paper or paper cassette is set normally.
Set the paper and paper cassette
normally.
(Ask customer for correct setting)
2
Faulty paper transfer path
Check the paper transfer path for presence of burrs,
foreign substances or dirt.
Clean or replace the parts concerned
3Faulty paper feed rolls
Check if the paper feed rolls feed the paper normally. Clean or replace the parts concerned
4
Faulty paper transfer rolls
Check the paper transfer rolls for evidence of foreign
substances, dirt, deformation, or malfunction.
Clean or replace the parts concerned
5Checking ROS ASSY for mounting
Check if ROS ASSY for mounting Replace the ROS ASSY
6
Faulty Imaging Unit (PHD)
Is the image quality improved if Imaging Unit (PHD) is
replaced
Replace the Imaging Unit (PHD)