3-218
RRP8.3 ACTUATOR EXIT (PL8.1.7)
Figure: ACTUATOR EXIT Removal
Removal
FUSER is high temperature after operation. Be careful when working it not to get
burning.
1) Remove the FUSER ASSY. (RRP8.1)
2) Remove the ROLL ASSY EXIT. (RRP8.2)
3) Holding the actuator of the ACTUATOR EXIT from the CHUTE EXIT/DUP of the FUSER ASSY, pull
down the ACTUATOR EXIT rightward an extract the left shaft of the ACTUATOR EXIT.
4) Pull out the ACTUATOR EXIT from the CHUTE EXIT/DUP rightward together with the SPRING ACTU-
ATOR (PL8.1.8).
5) Remove the SPRING ACTUATOR from the ACTUATOR EXIT.
Replacement
Replace the components in the reverse order of removal.