8-414
Magenta toner cartridge:equivalent to about 6,000 prints
Cyan toner cartridge:equivalent to about 6,000 prints
Fuser unit:equivalent to about 100,000 prints
5.3 Parts Requiring Periodical Replacement
Following parts are replaced when a certain number of sheets are printed ( life over) to prevent troubles.
FUSE ASSY:Equivalent to about 100.000 prints
RETARD ROLL:Equivalent to about 100,000 prints
6. Operating Environment
6.1 Installation Temperature / Humidity
Operated at: 5 to 32°C(41 to 90°F) / 15 to 85% RH
6.2 Installation Altitude
0 to 3,100m(10,170ft)
6.3 Installation Horizontality
Before and after the installation surface:within 5mm in 646mm
Right and left of installation surface:within 10mm in 560mm
6.4 Ambient Lighting
3000 Lux or less (without no direct sun beams)
7. Safety / Environment Conditions
7.1 Safety Standard
100V / 120V system
UL1950 3rd Edition
CSA C22.2 No.950-M95
220V / 240V system
IEC60950 2nd Edition
7.2 Laser Safety Standard
100V / 120V system
FDA21CFR Chapter 1, Subchapter J, Section 1010, 1040
220V / 240V system
IEC60825 Class 1 Laser Product
7.3 EMI
100V system