1-76
FIP-36 Full Stack (Output Bin Full)Step Check Yes No
1
Initial check
Check the following for damage.
SENSOR FULL STACK condition
Actuator condition
Replace the parts
concerned
With tool
Go to step [2]
Without tool
Go to step [3]
2
Check SENSOR FULL STACK
Does SENSOR FULL STACK function normally?
Using SENSOR FULL STACK diagnostic tool, check by
Diagnostic Input Test.
Replace PWBA
HNB MCU Go to step [3]
3Check HARNESS ASSY FRONT2 for signal
Is P/J139-6PIN <=> P/J139-5PIN +3.3VDC?
Replace PWBA
HNB MCU Go to step [4]
4Check HARNESS ASSY FRONT2 for signal
Is P/J139-4PIN <=> P/J139-5PIN +3.3VDC?
Replace SENSOR
FULL STACK
Replace
HARNESS ASSY
FRONT1A
Replace PWBA
HNB MCU