6-344
5.4 Front Assy In
5.4.1 Major functions
SENSOR ADC ASSY
Reads the density of the toner image prepared on the surface of BTR in the BTR UNIT ASSY (refer to
"5.7 BTR ASSY & Fuser") and feeds it back to the process control (refe r to "7.4 Process Control").
SENSOR TNR FULL
Detects that the toner collect space in the BTR UNIT ASSY (refer to "5.7 BTR ASSY & Fuser") has
become full of waste toner to be collected.
FUSER DRIVE ASSY
Supplies the drive to the FUSER ASSY (refer to "5.7 BTR ASSY & Fuser").