2-114
2.7.6 Write Life / Adjustment Data
After the PWBA HNB MCU was replaced, the NVM data read from the PWB before replacement and saved
in the text file are written to the new PWB. For this purpose, the text file created in 2.7 .5 “Save Life /
Adjustment Data" is used (.NSD extension).
1) Click the “Write Life / Adjustment Data” button, and the following screen wi ll appear.
2) Enter the file name of the text file created in "2.7.5 Save Life / Adjust ment Data" where the NVM data
to be written are saved in the [File Name] field.
3) Click the “Open” button.
4) Upon completion of writing, the message is displayed.
Successful termination: complete!
Unsuccessful termination: Write - in operation of a nonvolatile memo ry was not completed normally.