7521Plus / N N/B MAINTENANCE

8.8 HARD DRIVE TEST ERROR

Either an error message is shown , or the driver motor continues spinning , while reading data is from or writing data is to hard drive.

HARD DRIVE TEST ERROR.

Check if HDD’s cable installed to HDD and system properly (J516)

YES

Re-boot

OK?

NO

1.Try another known good HDD.

2.Try another known good HDD’s Transulation cable.

YES

Re-boot

OK?

NO

Replace mother BD or into board-level Troubleshooting.

Correct it then end.

Replace the faulty parts then end.

Board-level

Troubleshooting for hard drive test error.

Check the following parts for cold solder or one of the following parts on the mother-board may be defective, use an oscilloscope to check the following signal or replace the parts one at a time and test after each replacement.

Parts:

Signals:

 

U24, Q24

PDD[0~15]

RDDP[0~15]

Q25, R210

PDDACK#

RPDDACK#

RP46, RP47

PDIOR#

RPDIOR#

RP45, RP58

PDIOW#

RPDIOW#

R191, R211

PDDREQ

RCS[1,3]P#

R212, JS10

PDCS[1,3]#

RDAP[0~2]

C253, C250

PDA[0:2]

 

J516

PIDEACTS#

 

 