MiTAC 7521 PLUS/N service manual 7521Plus / N N/B MAINTENANCE, Pc-Card Socket Failure, Parts

Models: 7521 PLUS/N

1 180
Download 180 pages 51.44 Kb
Page 134
Image 134
Board-level

7521Plus / N N/B MAINTENANCE

8.13 PC-CARD SOCKET FAILURE

An error occurs when a PC card device is installed.

PC CARD TEST ERROR

1.Check if the PC CARD device is installed properly.

2.Confirm Pc card driver is installed ok.

YES

Test

Correct It.

OK?

 

 

NO

Try another known

Good PC card device.

 

YES

 

Re-test

Change the

 

 

faulty part

OK? NO

 

 

then end.

Change M/B or go into board-level Troubleshooting.

Board-level

Troubleshooting for

PC CARD test error

Check the following parts for cold solder or one of the following parts on the mother-board may be defective, use an oscilloscope to check the following signal or replace the parts one at a time and test after each replacement.

Parts:

SOCKET A

COMMON

SOCKET B

 

SIGNALS

SIGNALS

SIGNALS

U13, U505

ACD[0:15]

AD[0:31]

BCD[0:15]

U506, RP11

ACA[0:25]

C/BE[0:3]

BCA[0:25]

PAR

BIOWR#/BIORD#

RP12, RP14

AIOWR#/AIORD#

AINPACK#/AREG#

TRDY#

BINPACK#/BREG#

RP508, RP511

IRDY#

ARDY/AWAIT#

BRDY/BWAIT#

C279, C280

ABVD1/ABVD2

RESET#

BBVD1/BBVD2

SERR#

R566, R564

ARESET/AWE#

BRESET/BWE#

PERR#

C275, C274

AVS1/AVS2

BVS1/BVS2

STOP#

L43, L40, L38

ACE1#/ACE2#

DEVSEL#

BCE1#/BCE2#

C159, C122

A_CD#1/A_CD#2

FRAME#

B_CD#1/B_CD#2

C123, C138

AOE#/AWP

REQ0#

BOE#/BWP

 

GNT0#

 

C147, C139

 

 

 

CLKRUN#

 

C152, C146

 

 

 

133

Page 134
Image 134
MiTAC 7521 PLUS/N 7521Plus / N N/B MAINTENANCE, Pc-Card Socket Failure, An error occurs when a PC card device is installed