7521Plus / N N/B MAINTENANCE

8.11 SIO PORT TEST ERROR

An error occurs when a mouse or other I/O device is installed.

SIO TEST ERROR

1.Check if the mouse or others I/O device are installed (J507) properly.

(Including driver)

2.Check if CMOS COM port setting correctly.

Board-level

Troubleshooting for

SIO test error.

YES

Test

OK?

NO

Try another known good I/O device.

YES

Re-test

OK?

NO

Change M/B or go

into board-level Troubleshooting.

Correct

it and end.

Change the faulty part and end.

Check the following parts for cold solder or one of the following parts on the mother-board may be defective, use an oscilloscope to check the following signal or replace the parts one at a time and test after each replacement.

Parts:

Signals:

 

U27,U1

ISA_IRQ4

D/DCD#

Q1,R1

RS232_OFF#

COM1DCD#

 

D/RI#

COM1DSR#

J507

D/DTR#

COM1RXD

 

D/CTS#

COM1CTS#

 

D/TXD

COM1RTS#

 

D/RTS#

COM1TXD

 

D/RXD

COM1DTR#

 

D/DSR#

 

129

Page 130
Image 130
MiTAC 7521 PLUS/N service manual 129