8170 N/B MAINTENANCE
5.2 Intel 82845(Brookdale Memory Controller HUB)
System Bus singnals
Name | Type |
| Description |
HREQ[4:0]# | I/O | Host Request Command: These signals define the attributes of the | |
| AGTL+ | request. In Enhanced Mode HREQ[4:0]# are transferred at 2x rate. | |
|
| HREQ[4:0]# are asserted by the requesting agent during both halves | |
|
| of Request Phase. In the first half the signals define the transaction | |
|
| type to level of detail that is sufficient to begin a snoop request. In the | |
|
| second half the signals carry additional information to define the | |
|
| complete transaction type. | |
|
| The transactions supported by the MCH host bridge are defined in the | |
|
| Section 5.1. |
|
HTRDY# | I/O | Host Target Ready: HTRDY# indicates that the target of the | |
| AGTL+ | processor transaction is able to enter the data transfer phase. | |
RS[2:0]# | O | Response Status: RS[2:0]# indicates the type of response according | |
| AGTL+ | to the following the table: |
|
|
| RS[2:0] | Response Type |
|
| 000 | Idle state |
|
| 001 | Retry response |
|
| 010 | Deferred response |
|
| 011 | Reserved (not driven by MCH) |
|
| 100 | Hard Failure (not driven by MCH) |
|
| 101 | No data response |
|
| 110 | Implicit Write back |
|
| 111 | Normal data response |
SCS[11:0]# | O | Chip Select: These signals select the particular SDRAM components | |
| AGTL+ | during the active state. |
|
|
| Note: There are two SCS# signals per SDRAM row. These signals | |
|
| can be toggled on every rising system memory clock edge. | |
SMA[12:0] | O | Multiplexed Memory Address: These signals are used to provide | |
| AGTL+ | the multiplexed row and column address to SDRAM. | |
SBS[1:0] | O | Memory Bank Select: SBS[1:0] define the banks that are selected | |
| AGTL+ | within each SDRAM row. The SMA and SBS signals combine to | |
|
| address every possible location in a SDRAM device. | |
SRAS# | O | SDRAM Row Address Strobe: SRAS# is Used with SCAS# and | |
| AGTL+ | SWE# (along with SCS#) to define the DRAM commands. | |
SCAS# | O | SDRAM Column Address Strobe: SCAS# is used with SRAS# | |
| AGTL+ | andSWE# (along with SCS#) to define the SDRAM commands. | |
SWE# | O | Write Enable: SWE# is used with SCAS# and SRAS# (along with | |
| AGTL+ | SCS#) to define the SDRAM commands. | |
SDQ[63:0] | I/O | Data Lines: These signals are used to interface to the SDRAM data | |
| AGTL+ | bus. |
|
SCB[7:0] | I/O | Check Bit Data Lines: These signals are used to interface to the | |
| AGTL+ | SDRAM ECC signals. |
|
Name | Type | Description |
SCKE[5:0] | O | Clock Enable: These pins are used to signal a |
| AGTL+ | Powerdown command to a SDRAM array when entering system |
|
| suspend. SCKE is also used to dynamically powerdown inactive |
|
| SDRAM rows. There is one SCKE per SDRAM row. These signals |
|
| can be toggled on every rising SCLK edge. |
RDCLKO | O | Clock Output: RDCLKO is used to emulate |
| AGTL+ | for reads. This signal connects to RDCLKIN. |
SMA[12:0] | O | Multiplexed Memory Address: These signals are used to provide |
| AGTL+ | the multiplexed row and column address to SDRAM. |
RDCLKIN | I | Clock Input: RDCLKIN is used to emulate |
| AGTL+ | for reads. This signal connects to RDCLKO. |