B4. quantity Quantity to print (0-32000).
NOTE: Using 0 pre-images the field to reduce the imaging
time for labels. See "Batch Quantity Zero Method"
for more information.
Example {B,1,N,1 p
Defines a batch header that uses format #1 an d reimages all
fields using the online data. One label is printed with this batch.
Defining the Batch Control Field
The batch header must precede this field. The batch control field
defines the print job and applies only to the batch that
immediately follows.
Syntax E,feed_mode,batch_sep,print_mult,
multi_part,cut_type,cut_mult p
E1. E Batch Control Field.
E2. feed_mode Feed Mode. Options:
0Continuous Feed (default- all printers)
1On-demand (all printers)
E3. batch_sep Batch Separator (striped label in bet ween batches). Options:
0Does not print a separator (default- all printers)
1Prints a separator (all printers)
2Double-length separator- prints 2 tags
(9835 V5.0+, 9840 V6.0+, or 9850 printe r)
Note: Do not use batch separators with continuous
(non-indexed) supply. If using a stacker, the batch
separator is always 3.66 inches long.
E4. print_mult Number of tags with the same image. 0 is th e default.
1 to 999
E5. multi_part Number of ident ical parts on one tag. 0 is the default.
1 to 5