D e f i n i n g B a r C o d e F i e l d s

Each bar code field requires a separate definition.

Syntax B,field#,# of char,fix/var,row,column, font,density,height,text,alignment, field rot p

B1. B

Bar Code Field.

 

 

 

B2. field#

Unique number from 0-999(0-99for 9403/9805) to identify

 

this field.

 

 

 

B3. # of char

Maximum number of characters. If the bar code uses a check

 

digit, allow an extra character for the check digit. The actual

 

maximum number of characters is limited by the size of the

 

label and bar code density. Range: 0-2710(0-100for

 

9403/9805). Data Matrix can use up to 2710 numeric

 

characters or 2335 alphanumeric characters.

 

B4. fix/var

Fixed (F) or variable (V) length field.

 

 

 

 

 

 

Bar Code

 

Number of Characters

 

Fixed or

 

 

 

 

 

Variable

 

 

 

 

 

 

UPCA

 

 

12

 

F

 

 

 

 

 

 

UPCA+2

 

 

14

 

F

 

 

 

 

 

 

UPCA+5

 

 

17

 

F

 

 

 

 

 

 

UPCA+Price CD

 

 

12

 

F

 

 

 

 

 

 

UPCE

 

 

7

 

F

 

 

 

 

 

 

UPCE+2

 

 

9

 

F

 

 

 

 

 

 

UPCE+5

 

 

12

 

F

 

 

 

 

 

 

EAN8

 

 

8

 

F

 

 

 

 

 

 

EAN8+2

 

 

10

 

F

 

 

 

 

 

 

EAN8+5

 

 

13

 

F

 

 

 

 

 

 

EAN13

 

 

13

 

F

 

 

 

 

 

 

EAN13+2

 

 

15

 

F

 

 

 

 

 

 

EAN13+5

 

 

18

 

F

 

 

 

 

 

 

EAN13+Price CD

 

 

13

 

F

 

 

 

 

 

 

POSTNET

 

 

9 or 11

 

F

 

 

 

 

 

 

Defining Fields 3-9

Page 73
Image 73
Monarch 9805, 9835, 9820, 9830 manual F i n i n g B a r code F i e l d s, Each bar code field requires a separate definition